40
Inserting string
fuses into the
Fronius IG TL
- Carefully lift up the housing cover on
the bottom of the power stage set
- Reach into the opening
- Disconnect the ribbon cable from the
PC display board
IMPORTANT! If you add string fuses at a later date, follow all safety information.
CAUTION! If screws are not tightened correctly, there is a danger of damage re-
sulting from water getting into the device. The housing cover screws help to seal
the power stage set and must not be replaced by different screws.
2
1
4 x