Clock Date and time setting
IMPORTANT The correct setting of the time and date is required for:
- Correct functioning of solar module string monitoring
- The proper display of day and year values, the daily characteristic curve
- A correct logging function with a set logging interval
PS Status The status display of the last error that occurred in the inverter can be shown.
IMPORTANT Status codes 306 (Power low) and 307 (DC low) appear naturally every
morning and evening due to low solar irradiance. These status codes are not the result of
a fault.
- After pressing the ‘Enter’ key, the power stage set status and the last error that ocurred
are displayed.
- Use the ‘Up’ and ‘Down’ keys to scroll through the list.
- Press the ‘Back’ key to exit the status and error list.
Grid Status The last 5 grid errors that occured can be displayed:
- After pressing the ‘Enter’ key, the last 5 grid errors that occured are displayed.
- Use the ‘Up’ and ‘Down’ keys to scroll through the list.
- Press the ‘Back’ key to exit the grid error display.
Version Display of version number and serial number of the PC boards installed in the inverter (e.g.,
for service purposes)
FOL min Lower outer grid frequency limit value in Hz
Max. P AC Manual power reduction
GPIS Soft start function
GFDPRv Power reduction depending on grid frequency in %/Hz
GFDPRr Back to nominal power in %/s (after a power reduction caused
by the grid frequency)
Unit HH:MM, DDMMYYYY
Setting range Setting range Time / Date
Factory setting -
Unit -
Display range Display / Interface / Power Stage / EMI Filter
Factory setting -