35
EN
Press the feeder inching or gas test
button
The wirefeeder motors are calibrated while
not under load;
during calibration, the right-hand display
will read "run".
As soon as calibration - in the unloaded
state - is complete, the display will read
"St2".
Engage the drive units of both wirefee-
der motors (e.g. welding torch and cold
wire feeder) once again - the wirefee-
der motors must be under load (push-
pull calibration - engaged)
CAUTION!
Risk of injury from welding wire emerging at speed and from rotating cogs and drive
parts.
Keep the welding torch away from your face and body. Keep hands away from rotating
cogs and the wire drive.
Press the feeder inching or gas test
button
The wirefeeder motors are calibrated while
under load; during calibration, the right-
hand display will read "run".
If the push-pull unit does not need to be ca-
librated while under load (St2), the previ-
ously set values (e.g. "PPU" and "2") will
appear in the display when you press the
feeder inching or gas test button.
Calibration of the push-pull unit is complete
when the previously set values - e.g. "PPU"
and "2" - reappear on the display.
Press the Store button twice to exit
from the Setup menu
5
6
7
8