EasyManua.ls Logo

Fronius RI FB PRO/i - Page 40

Fronius RI FB PRO/i
44 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address
Signal
Activity/
Data type
Range
Factor
Process
image
Relative
Absolu-
te
Standard
Economy
WORD
BYTE
BIT
BIT
3
6
0 48 Process Bit 0 High
See table Value
Range for Process
Bit on page 43
ü ü
1 49 Process Bit 1 High
2 50 Process Bit 2 High
3 51 Process Bit 3 High
4 52 Process Bit 4 High
5 53
6 54 Touch signal gas nozzle High
7 55
TWIN synchronization
active
High
7
0 56
ExtOutput1 <= OPT_In-
put1
High
1 57
ExtOutput2 <= OPT_In-
put2
High
2 58
ExtOutput3 <= OPT_In-
put3
High
3 59
ExtOutput4 <= OPT_In-
put4
High
4 60
ExtOutput5 <= OPT_In-
put5
High
5 61
ExtOutput6 <= OPT_In-
put6
High
6 62
ExtOutput7 <= OPT_In-
put7
High
7 63
ExtOutput8 <= OPT_In-
put8
High
4
8 0–7 64–71
Welding voltage UINT16
0.0 to
655.35 [V]
100
ü ü
9 0–7 72–79
5
10 0–7 80–87
Welding current UINT16
0.0 to
6553.5 [A]
10
ü ü
11 0–7 88–95
6
12 0–7 96–103
Wire feed speed SINT16
-327.68 to
327.67 [m/
min]
100
ü ü
13 0–7
104–
111
7
14 0–7 112–119
Actual real value for
seam tracking
UINT16
0 to
6.5535
10000
ü ü
15 0–7 120–127
8
16 0–7 128–135
Error number UINT16
0 to
65,535
1
ü
17 0–7
136–
143
40

Table of Contents

Related product manuals