31
EN
press and hold the key; the cleaning device will perform the following functions in se-
quence: 
1. Cleaning is started
2. Wire cutter is activated
3. Compressed air/parting agent mixture is sprayed out of the cleaning opening
(5) Ready-to-clean indicator
lights up when the device is ready to clean
Robacta TC 2000, 
Robacta TC 2000 
US connections 
and mechanical 
components
Front of device
Rear of device
No. Function
(1) Level sensor
monitors the parting agent fill level in the dipping bowl
(2) Cleaning opening with internal parting-agent injection nozzle and brush seal
for cleaning the gas nozzle and the inside of the welding torch
for coating the gas nozzle and welding torch interior with parting agent
(3) Dipping bowl with spill tray
(4) Standard I/O connection socket (X1)
NOTE! The cleaning device can only perform these functions if the "Quick 
Stop" signal is set and the capacitors are charged.
(4)
(5)
(6)
(2)
(3)
(1)
(7)
(7)
(7)
(7)
(8)
(9)
(10)
(11)
NOTE! To avoid excess soiling, only use the device with the brush seal in 
place.
NOTE! If the dipping bowl is not in use, ensure that there are no parting agent 
residues left in the bottom.
NOTE! Ensure that there is always sufficient parting agent in the dipping 
bowl when in use (i.e., ensure that the fill level indicator never lights up).