51
EN
Cleaning program sequence - Robacta TC 2000 
Twin, Robacta TC 2000 Twin US
Program se-
quence with part-
ing agent 
nebuliser - over-
view
1. Weld
2. Clean gas nozzle tip and nozzle fitting
3. Spray parting agent
4. Weld
Program se-
quence with part-
ing agent 
nebuliser and dip-
ping bowl - over-
view
1. Weld
2. Cool welding torch in dipping bowl
3. Clean gas nozzle tip and nozzle fitting
4. Spray parting agent
5. Weld
Cooling welding 
torch in the dip-
ping bowl - de-
tailed description
Immersing the hot welding torch in the "Robacta TC Cool / Robacta TC Cool MD" parting 
agent has the following benefits:
- The spatter that has accumulated on the gas nozzle is loosened
- The welding torch is cooled down more
- The anti-adhesive agent in the "Robacta TC Cool / Robacta TC Cool MD" parting 
agent prevents renewed soiling
After welding, position the welding 
torch approximately 50 mm (1.97 in.) 
above the dipping bowl
Dip the welding torch vertically into the 
dipping bowl
Depending on the application, hold the welding torch in the dipping bowl for approxi-
mately 1 - 4 seconds so that any air in the torch can escape and the torch can cool 
sufficiently
Raise the welding torch back to its original position above the dipping bowl
Allow the welding torch to drip for approximately 1 - 4 seconds or blow down it with 
compressed air using the hosepack before bringing it back to its original position for 
cleaning
max. 75 mm
(2.95 in.)
(1)
NOTE! Do not dip the welding 
torch more than 75 mm (2.95 in.) 
into the dipping bowl. The gas 
holes (1) must remain dry.
1
2
3
4
5