52
Cleaning the gas
nozzle tip and
nozzle fitting - de-
tailed description
Position the welding torch approxima-
tely 50 mm (1.97 in.) centrally above
the middle of the cleaning opening
Move the welding torch vertically into
the cleaning/spray position
- see figure
Begin cleaning and wait for approxima-
tely 1 second
Spraying parting
agent - detailed
description
Applying parting agent evenly has the following advantages:
- reduced welding spatter accumulation
- prevents re-soiling
Maintain cleaning/spray position
- see figure
Spray welding torch with parting agent
for approximately 0.7 seconds
Move the welding torch to the start po-
sition above the cleaning opening -
approximately 50 mm (1.97 in.) cent-
rally above the middle of the cleaning
opening
- The cleaning operation is comple-
te and the welding torch is ready
for use again
NOTE! During the cleaning operation, blow out the welding torch with com-
pressed air through the hosepack - any remaining dirt or parting agent is re-
moved.
55 mm
(2.17 in.)
1
2
3
55 mm
(2.17 in.)
1
2
3