35 SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2-7
Non-CE Gas Conversion Instructions
Call Frymaster Service (1-800-551-8633) to determine the conversion kit appropriate for your configu-
ration and altitude. Contact your local FASC to order the kit and arrange for installation.
CE Gas Conversion Instructions
1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the CE
Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice or pilot.
2. Between a second family gas (G20 or G25) and a third family gas (G31 Propane) or vice versa:
a. Change the orifices.
b. Change the pilot orifice.
c. If the fryer is equipped with a Honeywell gas valve, adjust the gas pressure at the regulator
(refer to the CE Standard Burner Manifold Gas Pressure Chart). If the fryer is equipped with a
Robertshaw gas valve, the valve must be replaced (see Natural to Propane or Propane to Natural
below).
e. After adjustment, seal the adjustment screw.
3. If required by regulatory agencies in the country where installed, remove the rating plate and install a
new one. Call your local service agency or kitchen equipment supplier to order a new rating plate.
4. If the destination language changes, replace the labels. Call you local service agency or kitchen equip-
ment supplier for a label kit. The language of reference will be on the corner of the label.
The following gas-conversion components are available from your FASC:
Natural (G20/G25) to Propane (G31)
Package of 10 Burner Orifices: 826-1354; Pilot Orifice: 810-0427; Gas Valve: 806-
7102SP (needed to replace Robertshaw valves only)
Propane (G31) to Natural (G20/G25)
Package of 10 Burner Orifices: 826-1353; Pilot Orifice: 810-0426; Gas Valve: 806-
7101SP (needed to replace Robertshaw valves only)