35 SERIES GAS FRYERS
CHAPTER 4: FILTRATION INSTRUCTIONS
4-6
6. After the oil is completely filtered, close the drain valve and allow the fryer to refill. When bubbles ap-
pear in the oil, allow the filter to run 10 to 12 seconds longer to clear the lines and prevent shortening
from hardening in them, then PUSH the filter handle to the OFF position.
WARNING
The filter motor is equipped with a manual reset switch in case it overheats or an
electrical fault occurs. If this switch trips, turn off power to the filter system and allow
the pump motor to cool 40 minutes before attempting to reset the switch.
6. Remove the Power Shower and allow it to drain.
7. Make sure the drain valve is fully closed. Turn the gas valve to ON and allow the cooking oil/shortening
to reach setpoint.
NOTE: Ensure the fryer drain valve is fully closed before turning the fryer on. If the drain valve is not fully
closed, the fryer will not operate.
CHANGING THE FILTER PAPER
DANGER
Allow the filter pan to cool completely before attempting to change the paper.
Repeat steps 1 through 7 in Section 4.2.
Filter Handle in
OFF position
Drain valve in off position.