Section 6 Parameter Settings
76 FT722 & FT742 (RS485) – FF & PM Sensors – User Manual
6.4.19 MM: Reset or Query the Min/Max Recorded Wind Speed
$<listenerID>,MM<setting>*<checksum><cr><lf>
$<listenerID>,MM?*<checksum><cr><lf>
$<talkerID>,MM=<MinSpeed>,<MaxSpeed>*<checksum><cr>
<lf>
$aa,MM=xxx.x,xxx.x*hh<cr><lf>
Resets the min/max readings to their default (<MinSpeed> to 999.9
and <MaxSpeed> to 000.0) until the first reading
Minimum detected wind speed in current unit (m/s, knots or km/h)
Maximum detected wind speed in current unit (m/s, knots or km/h)
Example 1
Query the min/max wind speed readings
Query the min/max readings
$WI,MM=005.1,034.2*22<cr><lf>
Use the MM command to query the minimum and maximum wind speed readings that the
sensor has recorded since it was last switched on. The minimum and maximum readings are
set to their default values when an MMR, an RS or a DF set command is executed.