700-Bubbler-Man Rev 12 13 Feb 2020
Page 40/51
samples in seconds
aXSP30! Sets sample period to 30 seconds
The min value is 2 and max value is 60 seconds.
Default: 8
aXSU! Get stage units
Returns the code (0-5) for stage units (see list below in
“Set stage units”)
5 = Custom Units(Cu) – this indicates a slope was
manually set using the ‘aXSLP!’ command
aXSUP! Set stage units
P = 0 sets units to ft (feet) (slope=2.307)
= 1 sets units to in (inches) (slope=27.680)
= 2 sets units to m (meters) (slope=0.703)
= 3 sets units to cm (centimeters) (slope=70.3250)
= 4 sets units to mm (millimeters) (slope=703.250)
=.5* sets units to psi (slope=1.0)
* This is the default custom unit setting. Any other
slope entered using the “Set slope (aXSLP!)
command will result in an indication of 5 (custom
units). The user must be aware of the units
associated with the input slope value.
aXTU!
Get temperature
units
Returns either 6 (for F) or 7 (for C)
units
If P = 6 temperature is Fahrenheit
If P = 7 temperature is Celsius
aXTU6!a (set to F)
aXTU!a6 (get command confirms F)