vii
Conformity to the Low Voltage Directive in the EU (Continued)
5. The inverter should be used in an environment that does not exceed Pollution Degree 2 requirements. If
inverters are to be used in an environment with pollution Degree 3 or 4, place them in an enclosure of IP54
or above.
6. Install the inverter, Reactor, input or output filter in an enclosure with minimum degree of protection of
IP2X (Top surface of enclosure shall be minimum IP4X when it can be easily accessed), to prevent human
body from touching directly to live parts of these equipment.
7. Do not connect any copper wire directly to grounding terminals. Use crimp terminals with tin or equivalent
plating to connect them.
8. When you use an inverter at an altitude of more than 2000 m, you should apply basic insulation for the
control circuits of the inverter. The inverter cannot be used at altitudes of more than 3000 m.
9. Use wires listed in IEC 60364-5-52.
Power supply
voltage
Nominal applied motor
(kW)
Inverter type
Recommended copper wire size (mm
2
)
Main terminal *1
External braking
resistor connection
[DB, P(+)]
*1
Control circuit
control power
supply [24V+,-]
Aux main power
supply
[R0, T0] *1
Main power
input
Inverter
outputs
[U, V, W]
Inverter’s
grounding
[
G]
Three
-
phase 400 V
4.0
FRN0010LM2C-4
10
2.5
2.5 0.75 0.75 -
5.5
FRN0015LM2C-4
7.5
FRN0019LM2C-4
11 FRN0025LM2C-4
4
15 FRN0032LM2C-4
6
Power supply
voltage
Nominal ap
plied
motor (kW)
Inverter type
Recommended copper wire size (mm
2
)
Main terminal *1
DC reactor connection [P2, P3]
*1
Main power input
[L1/R, L2/S, L3/T]
With DCR
Without DCR
With DCR
Without DCR
Three
-
phase 400 V
4.0
FRN0010LM2C-4
2.5
2.5
2.5
2.5
5.5
FRN0015LM2C-4
4
7.5
FRN0019LM2C-4
4 6
11 FRN0025LM2C-4
4 6 4 -
15 FRN0032LM2C-4
6 10 6 16
Note: A box () replaces an alphabetic letter depending on the shipping destination.
Shipping destination: E (Europe)
*1 The recommended wire size for main circuits is for the 70°C 600 V PVC sheath wires used at an ambient temperature of