10-3
4) In the case of FRN001E1E-7U, motor cable shall be wired through the ring core (that comes
with the inverter), and the ring core shall be fixed by the EMC grounding flange.
Figure 10.2 Connecting Shielded Cables
5) If noise from the inverter exceeds the permissible level, enclose the inverter and its peripherals
within a metal enclosure as shown in Figure 10.3.
Figure 10.3 Installing the EMC Filter Built-in Type of Inverters into a Metal Enclosure
*
*
For FRN001E1E-7U, a ring core
comes with the inverter.
FRENIC-Multi