Table 10.2 Leakage Current from Inverters with an External EMC-complaint Filter (Optional)
Leakage current (mA) *
1)
Input power Inverter type Filter type
Normal Worst *
2)
FRNF12E1S-2U
FRNF25E1S-2U
FRNF50E1S-2U
FRN001E1S-2U
EFL-0.75E11-2 3.0 3.0
FRN002E1S-2U
FRN003E1S-2U
FRN005E1S-2U
EFL-4.0E11-2 3.0 3.0
FRN007E1S-2U
FRN010E1S-2U
EFL-7.5E11-2 11 11
FRN015E1S-2U
Three-phase
230 V
FRN020E1S-2U
EFL-15SP-2 20 20
FRNF50E1S-4U
FRN001E1S-4U
FRN002E1S-4U
FRN003E1S-4U
FRN005E1S-4U
15TDHS84 4.0 27.0
FRN007E1S-4U
FRN010E1S-4U
FN3011-30-61 0.4 3.1
FRN015E1S-4U
Three-phase
460 V
FRN020E1S-4U
FN301150-62 0.4 3.1
FRNF12E1S-7U
FRNF25E1S-7U
FRNF50E1S-7U
FRN001E1S-7U
FRN002E1S-7U
Single-phase
230 V
FRN003E1S-7U
30DKCS5 1.0 1.8
*1) The values are calculated assuming the power supplies of three-phase 240 V (50 Hz), three-phase
400 V (50 Hz), and single-phase 230 V (50 Hz).
*2) The worst condition includes a phase loss in the supply line.