6. SYSTEM DESIGN
ACCESSORY PARTS
Name and shape Q'ty Application
Installation
manual
1
Chamber
1
Air joint for connection
duct
Wire cover
1
Cover for extension wire
Screw
4
For attaching chamber
For attaching wire cover
Extension wire for louver
2
Extension wire for louver
Name and shape Q'ty Application
Extension wire for
receiver
1
Extension wire for
receiver
Wire (External output
)
1
For connect indoor unit
to relay of duct fan
(For single or multi)
Wire (External output
)
1
For connect indoor unit
to relay of duct fan
(For VRF)
Wire (External output
)
1
For connect indoor unit
to relay of duct fan
(For VRF)
Bolt
4
For attaching kit to
indoor unit
Cable tie
1
or ing wire
red
white
- (06 - 141) -
SYSTEM
DESIGN
SYSTEM
DESIGN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ABHG18LVTB and is the answer not in the manual?

Fujitsu ABHG18LVTB Specifications

General IconGeneral
TypeAir conditioner indoor unit
TimerYes
Multi-split-
Product colorWhite
Gas hose diameter12.7 mm
Hose length (max)25 m
Drain hose diameter25 mm
Liquid hose diameter6.35 mm
Refrigerating mediumR410A
Dehumidifying capacity2 l/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)5900 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)7500 W
Cooling capacity in watts (nominal)5200 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.61
Operating temperature (cooling) (T-T)-15 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Seasonal efficiency rating (cooling) (SEER)6.1
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)6000 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4
AC input voltage230 V
Current (cooling)9 A
Current (heating)12.5 A
AC input frequency50 Hz
Design load (cooling)5.2 kW
Energy efficiency class (cooling)A++
Annual energy consumption (cooling)298 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)1819 kWh
Indoor unit depth655 mm
Indoor unit width990 mm
Indoor unit height199 mm
Indoor unit weight27000 g
Indoor units quantity1
Indoor unit noise level (high speed)- dB