Ceiling type
Model: ABYG18KRTA
Outdoor temperature
Indoor temperature (°CDB / °CWB)
18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0
(°CDB) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
-10.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
-5.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
0.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
5.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
10.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
15.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
20.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
25.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
30.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
35.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52
40.0 3.93 2.01 4.45 2.29 4.69 2.64 5.02 2.96 5.36 3.24 5.53 3.71
46.0 3.07 1.22 3.47 1.40 3.66 1.61 3.92 1.80 4.19 1.97 4.32 2.26
NOTES:
• TC: Total Capacity (kW), SHC: Sensible Heat Capacity (kW)
• Values mentioned in the table are based on the following conditions:
– Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit)
- 390 -
6-2. Cooling capacity 6. Capacity table
OUTDOOR UNIT
AOYG18-24KBTA3
OUTDOOR UNIT
AOYG18-24KBTA3