Function setting procedure
1. Connect the power supply of the outdoor unit.
2. To enter the function setting mode, while holding down the FAN and the SET TEMP. but-
tons, press the RESET button.
Function setting
mode display
SET TEMP. ( )
RESET
FAN
3.
Press the SET TEMP.
or buttons to select the custom code that matches the setting
with the indoor unit. By selecting the appropriate custom code, the communication between
the indoor unit and the wireless remote controller become possible.
Custom code
(
--
-
)
The initial setting is " "
4. For confirming the custom code, press the TIMER MODE button to send the code to the in-
door unit.
5. Press the MODE button to enter the function setting mode.
6. Select the function number by pressing the or the button.
Each time the MODE button is pressed, it switches between the left digit and the right digit.
- 203 -
MULTI TYPE
5, 6 ROOMS TYPE