14-8. Wired remote controller (UTY-RVNYM)
DIP switch 1
SW1 Memory backup setting
SW2 Dual remote controller setting
¢
Switch location
¢
Dip switch setting
SW1: Memory backup setting (only for wired remote controller)
Set to “ON” to use batteries for the memory backup.
When batteries are not used, all of settings stored in memory will be deleted if there is a pow-
er failure.
SW1 Memory backup Factory setting
OFF Invalidity
ON Validity
NOTE: Never turn it on in the case of simple remote controller.
SW2: Dual remote controller setting
Set the remote controller SW2 according to the following table.
Number of remote controller
Primary unit Secondary unit
Factory setting
SW2 SW2
1 (Normal) OFF
2 (Dual) OFF ON
1 231 23
1 2 3
Indoor unit
Remote controller cable
Primary unit
Secondary
unit
Remote controller
- 251 -
MULTI TYPE
5, 6 ROOMS TYPE