Setting up each indoor unit
Repeat step from 1. to 8. to set up each indoor unit. If the custom code is other than " ", steps
from 1. to 2. and 8. need to be performed.

Resetting the power after setting up function of all indoor units
NOTES:
• If the reset is not performed, function cannot be read correctly.
• After all the functions have been set, the circuit breaker needs to be switched off for at least 2
minutes.
– After the 2 minutes has passed, power can be restored.
– The set function is stored in the PCB and will remain in memory even when the power of
indoor unit is turned off.
However setting function is effective after disconnecting the power supply and then recon-
necting it.
• Record the latest configuration of the indoor unit function setting on a label, and put the label
on the unit so it can be used for after-sales service operations.
Once the RESET button is pressed on the remote controller, the operation mode will be set to the
AUTO MODE.
Adjust the operation mode to either cooling or heating before starting the operation of the air con-
ditioner.
NOTE:
If custom code other than " " is set, the remote control must be set accordingly to the
indoor unit setting.
- 221 -
MULTI TYPE
5, 6 ROOMS TYPE

Table of Contents

Other manuals for Fujitsu ASYG12LMCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG12LMCA and is the answer not in the manual?

Fujitsu ASYG12LMCA Specifications

General IconGeneral
BrandFujitsu
ModelASYG12LMCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals