Installation and operation precautions Important notes
22 U41858-J-Z126-2-76
2.4.2 Operating precautions
w WARNING!
Danger of electric shock and fire
● Do not damage, break or modify the cables. Cable breaks can cause electric
shocks and fires.
v CAUTION!
Equipment damage:
● Do not cover or block ventilation openings.
● Install the SE server in a location away from direct sunlight and sources of heat.
● Install the Server Unit in an environment free of dust, corrosive gases, and salt
air.
● Install the business server in a location free of vibration and on an even surface
to prevent the business server from leaning.
● Do not run any cable beneath any equipment. Also, prevent cables from
becoming taut. Never disconnect the power cable of the Server Unit while
power is being supplied to the SE server.
● Keep objects off the rack and the rack components. Never use the rack as a
work area.
● Do not allow condensation to form. In winter, slowly raise the ambient room
temperature to prevent condensation from forming in the Server Unit.
● Use the SE server only after it has warmed up sufficiently.
● Operate the SE server away from noise-generating sources, such as photo-
copiers, air conditioners, and welding equipment.
● Take preventive measures to control electrostatic buildup. Note that carpets
often generate static charge which may cause the SE server to malfunction.
● When moving the business server, do not pull on the front cover. Doing so may
cause damage to the SE server.