Switching the server on and off Switching the SE300 on and off
U41858-J-Z126-2-76 73
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
19. April 2017 Stand 15:41.41 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303913_BA_Basis_update_2\prod_e\ba_basis.k08
8.1.3 Switching the SE server off
The following hardware components must be switched off in the specified order.
v CAUTION!
This does not disconnect the hardware components completely from the power
source (POWER STAND-BY). To cut the entire system off from the power source,
you must must disconnect the power distribution units from the power source
Notify Customer Support.
1. Switch off the optional Application Units
Before an Application Unit is switched off, the power-on indicator lights up green.
Ê Terminate the customer applications and the operating system properly.
The Application Unit is switched off automatically and enters standby mode.
The status indicator lights up orange. Check this before continuing.
i If the operating system does not automatically switch off the Application Unit,
hold the On/Off switch down for at least four seconds.
Alternatively, as the administrator or AU administrator you can switch the Application
Unit off using the SE Manager (menu Hardware Units[ <se server>] (SE<model>),
Units tab, Switch off symbol), see the “Operation and Administration” manual [5].
i The controls, indicators and further on/off options for the AU are described in the
"Additive Components" Operating Manual [4].
Further Application Units are switched off in the same way.
2. Switch off the Server Unit
Ê As the administrator, BS2000 administrator or a privileged operator, switch off the
Server Unit using the SE Manager (menu Hardware
Units[ <se server>] (SE<model>), Units tab, Switch off symbol), see the “Operation and
Administration” manual [5].
When the Server Unit is switched off, the BS2000 system is shut down properly taking
into account the remaining runtime specified.
Before the Server Unit is switched off, the power-on indicator lights up green, and after
it has been switched off, it lights up orange. Check this before continuing.
i The controls and indicators of the Server Unit are described in the "Server Unit
x86" Operating Manual [3].
Further Server Units are switched off in the same way.

Table of Contents

Other manuals for Fujitsu BS2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu BS2000 and is the answer not in the manual?

Fujitsu BS2000 Specifications

General IconGeneral
BrandFujitsu
ModelBS2000
CategoryServer
LanguageEnglish

Related product manuals