Switching the server on and off Switching the SE700 / SE500 on and off
U41858-J-Z126-2-76 81
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
19. April 2017 Stand 15:41.41 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303913_BA_Basis_update_2\prod_e\ba_basis.k08
Alternatively you can switch the Server Unit off by pressing the STAND-BY button on the
server's control panel (see page 44) or via the SVP console (menu item POWER STAND-
BY in AUXILIARY FRAME: POWER STAND-BY/IMPL). The BS2000 system should
already have been shut down.
i The control panel and SVP frames of the Server Unit are described in the "Server
Unit /390" Operating Manual [2].
3. Switch off the Server Units x86
Ê As the administrator, BS2000 administrator or a privileged operator, switch off the
Server Unit using the SE Manager (menu Hardware
Units[ <se server>] (SE<model>), Units tab, Switch off symbol), see the “Operation and
Administration” manual [5].
When the Server Unit is switched off, the BS2000 system is shut down properly taking
into account the remaining runtime specified.
Before the Server Unit is switched off, the power-on indicator lights up green, and after
it has been switched off, it lights up orange. Check this before continuing.
i The controls and indicators of the Server Unit are described in the "Server Unit
x86" Operating Manual [3].
Further Server Units x86 are switched off in the same way.
4. Switch off the MU
Ê Switch off the MU using the SE Manager (menu Hardware
Units[ <se server>] (SE<model>), Units tab, Switch off symbol), see the “Operation and
Administration” manual [5]
Before the MU is switched off, the power-on indicator lights up green, and after it has
been switched off, it lights up orange (item 11 in figure 10 on page 50). Check this
before continuing.
Redundant MUs are switched off in the same way.
5. Switch off the optional hardware components
Ê Switch off the ETERNUS LT40 S2 tape library using the On/Off switch on the front (see
the "Additive Components" Operating Manual [4]).
Ê Switch off any other connected hardware components.

Table of Contents

Other manuals for Fujitsu BS2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu BS2000 and is the answer not in the manual?

Fujitsu BS2000 Specifications

General IconGeneral
BrandFujitsu
ModelBS2000
CategoryServer
LanguageEnglish

Related product manuals