Appendix H Storage Migration Setting Files
H.2 Coding Conventions for the Storage Migration Setting File
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
1077
H.2 Coding Conventions for the Storage Migration Setting File
The following table shows the coding conventions for a Storage Migration setting file.
Keyword Coding conventions
Common
The Storage Migration setting file must be saved in the text format.
Contents of the file must be described in alphanumeric characters.
A keyword (Type, GROUP, OPEMODE, PATH, VOL) and its setting value must be connected
with "=" (equal).
Only a tab or space can be placed before a keyword (Type, GROUP, OPEMODE, PATH, VOL).
The number of setting values assigned to a keyword (Type, GROUP, OPEMODE, PATH, VOL)
with "=" must coincide with the number specified for each keyword. For more information on
the number of setting values for each keyword, refer to "H.1 Template File for Storage
Migration Settings" (page 1074).
Add the following information for each GROUP.
PATH (CMx, CAy, Pz, WWN), VOL
There must not be an overlap with the content of the Storage Migration setting file or the
migration information (GROUP, destination CA port, source WWN, source LUN, or destination
volume) of the path already configured.
GROUP
Up to 16 GROUPs can be specified.
For the setting range for each GROUP, refer to "H.1 Template File for Storage Migration
Settings" (page 1074).
OPEMODE
Specify "M", "M+QC", "M+FC", "QC", or "FC" for each GROUP (when OPEMODE is omitted, it is
regarded as though "M" is specified and only migration is performed).
For the setting range for each OPEMODE, refer to "H.1 Template File for Storage Migration
Settings" (page 1074).
PATH
Enclose the PATH and VOL for each GROUP with "{ }" (bracket symbols).
Describe all "PATHs" and then all "VOLs" for each GROUP.
Up to 8 PATHs per GROUP can be specified.
Separate the PATH setting values with "," (comma).
For the setting range of PATH, refer to "H.1 Template File for Storage Migration Settings"
(page 1074).
Describe the PATH in the following order.
If the migration destination is the ETERNUS DX8700 S3/DX8900 S3, "CEx" must be specified
when specifying a CE other than "CE0". If "CEx" is omitted, "CE0" is assumed.
If the migration destination is not the ETERNUS DX8700 S3/DX8900 S3, omit the "CEx"
setting or specify "CE0".
Start a new line for each PATH. Multiple PATHs cannot be described without breaking.
CE#, CM#, CA#, and Port# for the destination FC-Initiator port
WWN for the source FC-CA port
PATH=CEx, CMy, CAz, Pw, vvvvvvvvvvvvvvvv