32 U41578-J-Z875-1-76
Configuring the RAID system
Setting the controller parameters
Click the Controller Settings button. The following display will appear. Do not
change any of the checkboxes if not necessary. If you are using firmware
version 8.20, ensure that the checkbox for Enable Background Initialisation is
not
selected.
Basic
To obtain the best performance, set the Rebuild Rate to 20-30%. If you want to
return to your RAID level as quickly as possible after a failure, set the Rebuild
Rate to 50%.
With the exception of Expert Settings, the remaining file cards in this window
can be left with their default settings and should not be changed. For details on
Expert Settings, see the comments for this file card below.