U41578-J-Z875-1-76 77
FibreCAT S80 Quick Installation Guide
Installation for PRIMEPOWER
Documentation / Management Tool / Settings can be retrieved from:
● Internet ftp site
ftp://raid@ftp.fujitsu-siemens.com/(user: raid, Pass word: 4jumbo17)
Please be sure to have the following Microsoft Internet Explorer settings
activated:
IE: Tools => Internet options => Advanced => x Enable folder view for ftp sites
● Mandatory FibreCAT S80 FFx2 Firmware is 8.57
The needed Graphic User Interface Management tool is Spheras 1.3
How to install Spheras under Solaris can be found at ftp:
FibreCAT_S80/Manuals/Spheras-Manual_e.pdf
Installation procedure
1. Install the necessary (see Support Matrix) Fibre-Channel driver lpfc (and
hbAnyware) (pkgadd ...). The driver and hbAnyware is available on the
Control-CD delivered with each Primepower.
2. Adjust the lpfc.conf settings according the Solaris documentation
(FibreCAT_S80/Manuals/ …html)
3. Adjust the sd.conf (scan LUNs during boot)
4. Install Spheras (pkgadd ...)
5. Reboot using at lpfc.conf the settings (beside the others from above):
(Attention! delivery FC speed of FibreCAT S80 is 1 Gbit/s)
After reboot you should see a PSEUDO LUN at EUROLOGC
via /opt/FJSVmadm/sbin/hrdconf -l
link-speed=0 (mandatory for first boot)
topology=0 (mandatory for first boot)
automap=2 (mandatory for first boot)