78 U41578-J-Z875-1-76
Installation for PRIMEPOWER FibreCAT S80 Quick Installation Guide
6. configure the persistent binding using lputil of the automapped targets
(lputil can be found under /usr/sbin/lpfc/lputil)
The port numbers of the 4 possible FibreCAT S80 ports are, seen from the
rear: left hand controller top: 24.... bottom: 23....
Right hand controller top: 22... bottom: 21...
Attention! Use only port 21... for configuration!
7. Start Spheras GUI and set S80 FC speed to fix 2 GB/sec (under
Controllers/.../Fibre Channel)
8. Configure the LUNs as desired (64k Stripe Size is recommended!). Details
for configuring see FibreCAT_S80/Manuals/Spheras-Manual_e.pdf. Wait
until the Foreground init (FGI) has come to a complete stop (may take
several days!). Do not pull push disks during FGI is active!!
9. Set HBA
Fibre Channel Speed to 2 GB/s fix using lpfc.conf. Set topology=4
(AL, direct attached) resp. topology=2 (Point to Point, Switch attached)
10.Reconfiguration reboot: reboot <blank> - - <blank> -r
11.Label the LUNs using the format command
Attention
=> Never swap or change disks while the controller shelf is off!
=> Never switch off any extension shelf first, always first the controller shelf!
=> Always wait, until a long operation as been completed (rebuild, FGI,
expand cap etc.)!