U41578-J-Z875-1-76 75
Appendix
Like all batteries, backup batteries have reconditioning, discharge and charging
cycles. On new systems the battery backup requires charging before system
startup.
IMPORTANT: Despite the latest, process-controlled pulse charging technology,
initial battery charging can take up to 36 hours. Obviously, during this time
cache data security cannot be guaranteed. It is therefore a good idea to carry
out initial battery charging immediately after the configuration procedure and
before any user data has been stored. You can use the initialisation time also to
charge the battery. Click the Recondition button in the Actions box. The
message Reconditioning Active will appear in the Status box. The functions of
the other parameters and buttons in this form are clear from their names and do
not therefore require explanation. Use these as required. The Refresh button in
the Actions box is used to refresh the display and not to refresh the battery.
Note: The guaranteed cache hold time is 68 hours.