U41578-J-Z875-1-76 81
FibreCAT S80 Quick Installation Guide Installation for PRIMERGY
use stripe size 64k! Configure LUN numbers in ascending order
without leaving “gaps”
Be sure to configure a ”Mini LUN 0” (10MB), which is visible for all attached
hosts!
(It is important to have explicit LUN 0, not an different number)
Remember Service bulletin SB-STO-0309 “Windows Default Maximum-
Queue-Depth Setting for FibreCAT S80” .
Use Windows disk manager “Scan for new devices”
Write signatures to the new disks
Attention
=> Never swap or change disks while the controller shelf is off!
=> Never switch off any extension shelf first, always first the controller shelf!
=> Always wait, until a long operation as been completed (rebuild, FGI,
expand cap etc.)!