RX300 S5 Operating manual 51
Hardware installation Installing/removing the server in/from the rac
k
Inserting the server
Figure 11: Inserting the server
V CAUTION!
Ensure that the safety lock has been inserted before the server is
inserted (see figure 9 on page 49).
V CAUTION!
At least two people are needed to position the server in the rack.
Ê Extend the interior telescopic rails completely to the front (1).
I They must click into place so that they can no longer be moved.
Ê Insert the prepared server into the protruding interior telescope rails (2) until
the rails engage.
Ê Release the locking mechanism of both telescopic rails - see (3a) for fully
extending rails and (3b) for partially extending rails.
Ê Push the server as far as it will go into the rack (4).
Ê Fasten the server to the rack (5) using the two knurled screws (front panel).
Ê Route the cables as described in the technical manual for the rack in
question with the server pushed in.
1
2
4
4
5
5
3a
3b