EasyManua.ls Logo

Fujitsu PRIMERGY RX600 S6 - Page 50

Fujitsu PRIMERGY RX600 S6
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50 Operating Manual RX600 S6
Hardware installation
© cognitas. Gesellschft für Technik-Dokumentation mbH 2011 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-11938-001.fm
Installation requirements for AC non redundant configurations
For systems not requiring AC redundancy, the power supply subsystem can be
installed with up to 4 PSUs. The PSUs can be connected to a single or multiple
AC sources.
Three power supply modules are capable of handling the maximum power
requirements for a fully configured PRIMERGY RX600 S6 server system, which
include the following:
Four processors
1024 GB of memory
Eleven PCIe add-in cards (including the SAS/SATA RAID controller card)
Eight hard disk drives and/or solid state disks
One optical drive
One tape drive
The hot swap feature allows the user to replace a failed power supply module
without affecting the system functionality.
PSU Configuration Max. DC Loading DC Redundancy
1+1 (2 PSUs) 830W Yes
2+1 (3 PSUs) 1580W Yes
3+1 (4 PSUs) 2320W Yes
Table 3: Maximum DC Loading Requirements

Table of Contents

Other manuals for Fujitsu PRIMERGY RX600 S6

Related product manuals