RX600 S6 Operating Manual 99
CSS components
Figure 21: Installing the 2.5-inch HDD/SSD module
Ê Carefully push the HDD/SSD module into the empty slot (1) until it stops.
Ê Push the handle completely (2) in the direction of the arrow until the locking
mechanism engages.
8.1.3.4 Removing the HDD/SSD module
V CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the control LEDs for the
corresponding HDD/SSD modules (see "Indicators on the hot-plug
HDD/SSD modules" on page 62).
Under no circumstances should you remove an HDD/SSD module
while the system is in operation if you are not sure that the hard disk
drive or solid state disk is operated by a RAID controller and belongs
to a disk array that is operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
/