98 Operating Manual TX150 S7
Hot-plug components CSS components
8.1.2.5 Removing/installing the dummy module
Free slots are provided with dummy modules. Remove the dummy module
before installing an additional HDD module.
Figure 24: Removing/installing the dummy module (example: 3.5-inch dummy module)
Ê Press both tabs on the dummy module together until the locking mechanism
disengages (1).
Ê Pull the dummy module out of the slot (2).
To install a dummy module, follow the same procedure in reverse order.
V CAUTION!
Keep the dummy module for future use. If you have removed a HDD
module and do not install a new one in its place, put the dummy module
back in its place for cooling, to comply with EMC regulations (regulations
regarding electromagnetic compatibility), and for protection against fire.
Ensure that the dummy module engages correctly in the bay.