48 Service Supplement TX200 S6
Replacing the system board
Ê Insert the system board by holding it at a slight angle. Slide the connectors
into the connector panel.
V CAUTION!
Do not lift or handle the system board by any of its heat sinks!
Ensure not to damage the EMI springs to comply with applicable EMC
regulations and satisfy cooling requirements and fire protection
measures.
Ê Lower the system board carefully into the housing.
Ê Adjust the system board with the help of the centering holes (see the yellow
circles). If necessary adjust the position of the system board with a gentle
twisting motion.
Ê Fasten the system board with the ten screws.
I Tighten the screws in a cross diagonal pattern.
Ê Reconnect the cables to their original connectors (see the cabling plans in
the Options Guide).
Ê Install the memory modules (for a description see the Options Guide).
Ê Install the heat sinks (for a description see the Options Guide).
Ê Install all controllers in their former slots (for a description see the Operating
Manual and Options Guide).
Ê Reinstall the system fan 1 (or 1&3) and the system fan 2 (or 2&4) (for a
detailed description see the Options Guide).
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
Ê Reconnect all external cables.
Ê If applicable, activate TPM functionality in the system BIOS under Security
> TPM (Security Chip) Setting > Security Chip. For more information, please
refer to the BIOS manual.
V CAUTION!
After installing the new system board, it is necessary to update system
specific data (e. g. BIOS, iRMC S2 firmware) to ensure proper operation
(BIOS flash floppy disk or BIOS Flash Memory Stick, refer to the BIOS
manual for a detailed description).