5.2 Environmental Conditions
Characteristic DO–160D
Sectio
n
Cat. Condition
Temperature / Altitude 4.0
Low ground survival
temperature
4.5.1 – 55°C
Low operating temperature 4.5.1 – 20°C
High ground survival
Temperature
4.5.2 + 85°C
High Short-time Operating
Temperature
4.5.2 + 70°C
High Operating Temperature 4.5.3
C1
+ 55°C
In-Flight Loss of Cooling 4.5.4 Z
No auxiliary cooling
required
Altitude 4.6.1 C1 35 000 ft
Temperature Variation 5.0 C
2°C change rate minimum
per minute
Humidity 6.0 A
Shock 7.0 A
6 G operational shocks
20 G Crash Safety
Test Type R in all 6
directions
Vibration 8.0 S Vibration Curve M
Explosion Proofness 9.0 X No test required
Water Proofness 10.0 X No test required
Fluids Susceptibilities 11.0 X No test required
Sand and Dust 12.0 X No test required
Fungus Resistance 13.0 X No test required
Salt Spray 14.0 X No test required
Magnetic Effect 15.0 Z Less than 0,3 m
Power Input (DC) 16.0 B
Voltage Spike Conducted 17.0 A
Audio Frequency Conducted
18.0 A