21
2.3 Wiring of Transceiver Unit
Fabrication of cable TTYCY-3S, 65S1213/65S1239
Cut the cables to fix them at the plate in the unit with a cable tie, leaving some slack for
servicing and checking ease. Shield wire should be fixed at the plate. Twist pair cables together
before connecting to the board.
5
10
Shield
Crimp-on Lug
FV2-M4
Secure armor by clamp.
Rubber Gasket
Washer
145
160
Cradle
Fixing plate
Fasten the shield together with
the fixing plate on the cradle.
Anticorrosive Sheath
Vinyl Sheath
Armor
Fabrication of cable TTYCY-3S
When using the optional junction box, fabricate the cable same as the above figure.