EasyManua.ls Logo

Furuno DS-80 - JPW Board (65 P6010); Distribution Box DS-801; DIP Switch S4 Settings

Furuno DS-80
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
Power switch: Upper
Set to OFF.
Distribution box DS-801
ON
OFF
R100
R145
R96
R87
R40R29
R36
R27
3.7 DIP Switch Settings
JPW Board (65P6010)
S4-#6
The default setting (OFF) outputs only sentences VBW and VLW of all NMEA sentences input.
DIP switch S4-#6 setting OFF ON
Output NMEA sentences VBW, VLW All NMEA sentences
S4-#8
Select whether to output or don't output the distance run pulse if an error occurs, when
DOPPLER is selected at SPD DATA in the SYSTEM MENU.
DIP switch S4-#8 OFF ON
Distance run pulse Output stopped Output not stopped
Note: S4 #1-#5, #7, S2 #3, #4 should remain OFF, the default setting.
JPW Board (65P6010)
S4
Distribution box, cover removed

Table of Contents

Other manuals for Furuno DS-80

Related product manuals