1. INSTALLATION
1-7
1.3 Rudder Reference Unit FAP-6112
Note 1: This unit is not required for Fantum Feedback
TM
. For details of Fantum
Feedback
TM
, see “Fantum Feedback
TM
“ (page 1-8).
Leave sufficient space around all moving parts.
The unit must be fastened to the rudder as shown below, where the following condi-
tions are met:
350 mm(13.8”) <Y2 < 540 mm(21.3”)
X1 = X2
Y1 = Y2
Use four self-tapping screws (supplied) to fasten the rudder reference unit.
After mounting the RRU unit adjust it as follows:
1. Center the rudder.
2. With the rudder centered, check if the notch is aligned with the arrow mark. If it is, no
further adjustment is necessary. If not, go to step 3.
3. Loosen the screw on the arm of the RRU then align notch with the arrow mark.
4. Tighten the screw.
X1
X2
Y1
Y2
90°
Top view
Arrow
mark
RRU
Rudder
Arrow mark
Notch
90 degrees
RRU may be installed at
either side of rudder.
Align the notch on the shaft with
the arrow mark as shown below.