2. WIRING
2-4
2.5 MULTI Cable
Use the MULTI cable for the NMEA0183 equipment, external buzzer to supply power
to the CAN bus. The connector has 9 wires and connector (SMP-11V). Use the table
below for reference and connector (SMD-11V, local supply) when connecting the
MULTI cable.
2.5.1 How to set up NMEA0183 data output
Note: To set up data input from NMEA0183 equipment, see "NMEA0183 equipment
data input" on page 2-7.
1. Tap the [Home] icon ( ) to show the home screen and display mode
settings.
2. Tap [Settings], then drag the menu to show [Initial Setup]. Tap [Initial Setup].
3. Drag the menu to show [NMEA0183 Output], then tap [NMEA0183 Output].
4. Tap [Baud Rate] to set the output baud rate. Available options are [4,800], [9,600]
and [38,400].
5. Tap the appropriate setting then tap the icon.
6. Tap [NMEA-0183 Version] to set the version. Available options are [1.5], [2.0] and
[3.0].
7. Tap the appropriate setting then tap the icon.
8. Select the appropriate sentences to output, then tap the flipswitch to set the
sentence to [ON].
9. Tap the [Close] icon at the top right of the screen to close the menus.
Wire color Function Remark (Port No.)
White NMEA-TD-A
NMEA0183 Output
Blue NMEA-TD-B
Gray EXT_BUZZER External buzzer ON/OFF
Red +12 V External buzzer power (12 V)
Orange EVENT_SW Event switch (MOB, etc.)
Black GND Grounding
Purple POWER_SW
Power switch
Brown DC_N
Black DRAIN Grounding