3. HOW TO SET UP THE EQUIPMENT
3-5
3.3 Initial Setup
This section shows you how to set your system according to the sensors you have
connected.
Note: Some units are set to metric in this section, actual setting ranges vary
depending on the unit of measurement set in the [Units] menu.
1. Tap the [Home] icon to show the home screen and display mode settings.
2. Tap [Settings] to show the [Settings] menu.
3. Drag the main menu, then tap [Initial Setup] to show the [Initial Setup] menu.
4. Referring to the tables on the following pages, set your equipment.
[Initial Setup] menu - [GPS POSITION]
Engine & Tank, Instruments Setup
Menu item Description Options (setting range)
[Longitudinal (from
bow]
Referring to the figure on the
right, enter the GPS antenna
positioning bow-stern
(Longitudinal) and
port-starboard (Lateral)
position from the origin.
0 (m) to 999 (m)
[Lateral (-Port)] -99 (m) to +99 (m)
Port-side is negative,
Starboard-side is positive.
Menu item Description Options (setting range)
[Boat Length] Set the length of your boat. 0 (m) to 999 (m)
[Size of Static Icon] Set the size of static (such as own ship)
icons.
50 to 150
[Depth Display] Select the start point for depth measure-
ment.
[Under Keel],
[Under Sea Level]
[External Transducer
Draft]
Set the draft external transducers other
than internal fish finder, networked or
multi-beam sonar.
For internal/network transducers, set
the draft from Home screen[Set-
tings][Sounder][Transducer Draft].
For multi-beam sonars, set the draft
from Home screen[Settings][Multi-
beam Sonar][Initial Setup][External
Transducer Draft].
0.0 (m) to 99.9 (m)
[Keel Draft] Set the keel draft. 0.0 (m) to 99.9 (m
Menu item Description Options (setting range)
[Engine & Tank Auto-
matic Setup]
See "[Initial Setup] menu - [Engine & Tank Automatic Setup]" on page 3-
10.
[Engine & Tank Manual
Setup]
See "[Initial Setup] menu - [Engine & Tank Automatic Setup]" on page 3-
10.
[Graphic Instruments
Setup]
See "[Initial Setup] menu - [GRAPHIC INSTRUMENTS
SETUP]" on page 3-9.