GALaxy eHydro Elevator Controller Section 7 Main CPU Adjustable Variables
7-3
Table 7-2: Car Timers
Field Variable
Min
Max
Initial
Units
Description
AdvDoor
EnTim
0
240
0
sec
Advanced Door Enable Time. Door open advance
enable time to open the opposite door when
operating with non-simultaneous doors. If there is a
request for both doors, instead of waiting for the first
open door to close completely before opening the
second door, the second door starts to open after the
advance door enable time while the first door is
closing.
Att Buz Delay
0
900
60
sec
Attendant Buzzer Delay. Buzzer sounds if a hall call is
entered and the car has not started moving within
this delay time. This function is disabled when set to
zero.
AttBuz On Tim
1
30
5
sec
Attendant Buzzer On Time. Cycle on timer to turn
attendant buzzer on and off once attendant delay
time function has been met (See ATTBuz Delay).
AttBuzOff Tim
0
30
0
sec
Attendant Buzzer Off Time. Cycle off time to turn
attendant buzzer on and off once attendant delay
time function has been met (See ATT Buz Delay).
Buzzer will stay on continuously if this timer set to
zero.
AutoSwg
DODly
0
10
1
sec
Auto Swing Door Open Delay. Delay time to enable
the auto swing door open output.
CB Door Time
1
3200
60
sec
Code Blue Door Time. Door time for Code Blue
operation once elevator is at the emergency floor
before EMS is energized
CC Dwell
1
60
2
sec
Car Call Dwell. Door open dwell time when answering
a car call only.
Chime on CC T
0.1
2
0.2
sec
Chime on Car Call Time. Handicap buzzer on CC.
Length of beep time.