GALaxy eHydro Elevator Controller Section 7 Main CPU Adjustable Variables
7-18
Table 7-4: Service Options
Field Variable
Min
Max
Initial
Units
Manual Dir En
0
4
0
-
Attendant Manual Direction Enable.
1 = Works in conjunction with the ATTUP and ATTDN
to determine direction of travel.
2 = Reads the ATTUP input and use it as a START
button.
4 = Will not allow car calls to be registered until the
door is fully closed.
No Psg RunCnt
0
10
0
count
No Passenger Run Count. When set to a number
other than zero, the car call antinuisance feature is
activated. This count is the number of times the car
will run from a car call without detecting that a
passenger has broken the detector edge. Once the
count is reached, all remaining car calls will be
cancelled.
PI Serv Msg 1
0
Max
Service
0
Svc #
PI Service Message 1. When the car service matches
this number, user message 1 is sent to the PI display.
This will correspond to user PI display message 17.
PI Serv Msg 2
0
Max
Service
0
Svc #
PI Service Message 2. When the car service matches
this number, user message 2 is sent to the PI display.
This will correspond to user PI display message 18
PI Serv Msg 3
0
Max
Service
0
Svc #
Service Message 3 Display. Used for Custom
messages. Need to be programmed by CE electronics
and GAL for special messages
Retrn To Lbby
0
7
0
-
Return to Lobby Option.
+1 = Cycle door at lobby,
+2 = Cancel car calls when activated,
+4 = Cycle door on reversal.