GALaxy eHydro Elevator Controller Section 7 – Main CPU Adjustable Variables
7-19
Table 7-4: Service Options
Return To Lobby Door Select. This variable allow you
to specify door open type on 'Return to Lobby'
service.
0 = The car will open only front door
1 = The car will open only rear doors
2 = The car will open both front and rear
Sabbath Disable Control Variable. - Add all numbers
of the features you want to disable while in Sabbath
operation:
+1 = PIs,
+2 = Lanterns,
+4 = Directional arrows
Sabbath Enable Control Variable.
0 = Disables all options.
+1 = Allow IR momentarily to override Sabbath
operation.
+2 = Lobby Dwell time in Sabbath follows handicap
door dwell time instead of the lobby dwell time.
+4 = Wait until car is at lobby to turn off Sabbath
operation
Sabbath Enable control:
+1 = When the car is placed on Sabbath operation, it
waits to go to the lobby before switching to Sabbath
Operation,
+2 = Uses the cab lanterns as directional arrows.
This allows people on the hall ways to know direction
of travel for the elevator
Sabbath Collective Mode.
0 = Down collective car calls