GALaxy eHydro Elevator Controller Section 7 Main CPU Adjustable Variables
7-21
Table 7-4: Service Options
Field Variable
Min
Max
Initial
Units
Stop At Lobby
0
15
0
-
Stop at Lobby.
0 = do not automatically stop at lobby,
+1 = The car will stop at the lobby when the car is
traveling up and the car is below the lobby floor.
+2 = The car will stop at the lobby when the car is
traveling down and the car is above the lobby floor.
+3 = The car will stop at the lobby when traveling in
either direction.
+4 = Stop at lobby with any onward call past the
lobby.
+8 = Recall to the lobby
Svc Light Ctl
0
Max
Service
0
Svc #
Service Light Control. When the configuration file
parameter cons[servOUT] is set to 1 or 2, the service
output SERVO will turn on when the car service
matches the car service number in this parameter.
VIP Lant Ctrl
0
3
0
-
VIP lantern Control.
0 = Do not ring lanterns on VIP,
1 = Ring up or down lantern at VIP floor when the
door is fully open,
2 = Ring up or down lantern at VIP floor before the
door is opened.
VIP multicall
0
1
0
-
VIP Multiple Calls.
0 = VIP feature works as single call
1 = The car will be allowed to make multiple VIP calls
until no more car calls are entered and until the VIP
sequence time-out timer is expired.
VIP Operation
0
3
0
-
VIP (Priority Call) Operation.
+1 = Cancel hall call if no cars available for VIP call.
+2 = Cancel car call upon initiation of being selected
as the VIP car.

Table of Contents