3.6
Setting
Irrigation
Start
Times
M
Tu
W
Th
F
SaSu
In
this
step,
up
to
4
separate
irrigation
start
times
can
be
programmed
for
a
selected
day
for
the
valve
being
programmed.
The
selected
valve
will
open
at
each
of
the
start
times
set,
for
the
irrigation
duration
set
as
described
in
Section
3.4.
1.
Press
©
until
the
START
|
appears.
The
word
or
the
last
start
time
set
will
ee
appear
on
the
display.
F605
-
DCs
2.
Press
©)
.
The
displayed
item
blinks
(OFF
or
last
start
time
entered).
3.
Set
the
desired
start
time
by
pressing
®
and
©.
(Take
note
of
the
AM
and
PM
designations).
Repeat
actions
2
and
3
to
set
start
times
Il,
III
and
IV,
as
needed.
4.
To
cancel
a
specific
start
time,
select
it
by
pressing
©
.
Next,
press
®©.
The
hour
digits
blink.
Press
@
or
©
until
the
word
OFF
appears
on
the
display.
5.
To
program
another
valve,
select
it,
and
repeat
the
above
steps,
starting
from
section
3.3
above.
12

Other manuals for Galcon S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Galcon S Series and is the answer not in the manual?

Galcon S Series Specifications

General IconGeneral
BrandGalcon
ModelS Series
CategoryController
LanguageEnglish

Related product manuals