Page 22 of 35 GTLE Error list GTLE Operating Manual
14. Possible faults
Message-
number
Sensor-/
actuator
number
Messagetext Reason Action
1 S9 Emergency stop pressed (S9)
The emergency stop button (red-yellow button) was
pressed on the control unit, which is mounted on the
lift system.
Turn the mushroom button counter clockwise to disable the
emergency stop.
2 S5 Safety catcher triggered (S5)
Safety catcher has tripped or the lift is vibrating
heavily.
The stair lift is now blocked by the safety device and must be
released again by a service technician.
3 S6 Emergency-crank plugged-in (S6)
The emergency crank is in the emergency crank
holder on the lift.
Remove the emergency crank from the bracket.
4 S7 Emergency-end right side (S7)
The stair lift has gone over the landing sensor
(loading point) on the right-hand side.
1. Using the emergency crank, crank the stairlift approx. 10 cm
to the left.
2. Check whether the landing sensor S16 switches. "Stop right"
appears on the display
3. Approach the stop again. If this error occurs again, please
contact a service technician immediately.
5 S8 Emergency-end left side (S8)
The stair lift has gone over the landing sensor
(loading point) on the left-hand side.
1. Using the emergency crank, crank the stairlift approx. 10 cm
to the right.
2. Check whether the landing sensor S15 switches. "Left stop"
appears on the display
3. Approach the stop again. If this error occurs again, please
contact a service technician immediately.