30 of 35 Maintenance manual GTLE Operating Manual
18. Maintenance manual
Platform - stairlift GTL____________
Serial-Nr.: ______________________
W2 For difficult use indoors or outdoors with corrosive ambient media.
Maintenance interval 2x per year, every 6 months
W1 For normal use indoors or outdoors without corrosive ambient media.
Maintenance interval 1x per year
Lfd.
Nr.
Work to be carried out
(Only by qualified technician)
Equipment / Materials
W1
W2
Comments
1.
Columns, fastening construction
If present
1.1
Checking for tight fit
1.2
Checking for corrosion, chipping and deformation
1.3
Treatment of the visible parts in the interior with preservative
K1 / K2
2.
Rail
2.1
General inspection of the roadway
2.1.1
Check the roadway for corrosion and clean the surfaces
R1 / P1
2.2
Fastening
2.2.1
Check for tightness
2.2.2
Look for break-outs and deformations
2.3
Track profile fasteners
2.3.1
Check for tight fit
2.3.2
Search for break-outs and deformations
2.4
Rail tube end caps and screw covers
If present
2.4.1
Check for completeness, replace covers if necessary
2.4.2
Check for tight fit

Table of Contents