GTLE Operating Manual Maintenance manual Page 31 of 35
Lfd.
Nr.
Work to be carried out
(Only by qualified technician)
Equipment / Materials
W1
W2
Comments
2.5
Spiral cable Guide rod
If present
2.5.1
Check for tight fit
2.5.2
Check the insulation of the cable, look for chafing points and kinks in
the cable.
2.6
Limit switches and charging points
2.6.1
Check for corrosion and clean the contact surfaces.
K3
2.6.2
Check function and tight fit of switches and screw connections.
2.7
Equipotential bonding conductor connection
2.7.1
Check for tight fit
2.8
Charging cable
2.8.1
Check the insulation of the cable and check for tight fit, look for
chafing and kinks in the cable.
K3 / K4
2.9
Rail profiles
2.9.1
Look for chipping, deformation and wear
2.9.2
Remove dirt
R1 / P1
3.
Lift unit
3.1
Guide rollers
3.1.1
Search for corrosion, chipping and deformation
3.1.2
Check for tight fit
3.1.3
Check function and adjustment
3.1.4
Check for noise and wear, lubricate bearings
S1 / S2 / S3
3.1.5
Remove contamination
R1
3.1.6
Check the preservation of the bearings and moving parts, if
necessary spray the areas with preservative.
K2