Page
32 of 35 Maintenance manual GTLE Operating Manual
Lfd.
Nr.
Work to be carried out
(Only by qualified technician)
Equipment / Materials W1 W2 Comments
3.1.6
Check the preservation of the bearings and moving parts, if
necessary spray the areas with preservative.
K2
3.2
Drive unit
3.2.1
Check for corrosion, chipping, noise, wear and deformation.
3.2.2
Check adjustment, function and tight fit and lubricate bearings.
S1 / S2 / S3
3.2.3
Check for leaks in worm gears
3.2.4
Check preservation of bearings and moving parts, spray areas with
preservative if necessary.
K2
3.3
Safety gear
3.3.1
Check for corrosion, chipping, noise, wear and deformation.
3.3.2
Check adjustment, tight fit and ease of movement of moving parts.
3.4
Safety barriers
3.4.1
Check position, function, play and lubricate bearing points
S1 / S2 / S3
3.4.2
Check for corrosion, noise and contamination
R1
3.4.3
Check function and tight fit of barrier motor
3.4.4
Check function of slipping clutch
3.4.5
Check function and tight fit of cable for drive-up ramps
3.4.6
Check for sluggishness, corrosion and deformation of cable and
3.4.7
Check the preservation of the bearings and moving parts, if
necessary spray the areas with preservative.
K2
3.5
Platform
3.5.1
Check for corrosion, chipping, noise, wear and deformation.
3.5.2
Check position, function, fastening, tight fit and lubricate bearing
S1 / S2 / S3
3.5.3
Check function and tight fit of platform motor
3.5.4
Check the preservation of bearings and moving parts, if necessary
spray the areas with preservative.
K2
3.6
Drive-up ramps
3.6.1
Check for corrosion, noises and deformations.