Page 27 of 35 GTLE Error list GTLE Operating Manual
Message-
number
Sensor-/
actuator
number
Messagetext Reason Action
49 S12 Ramp left side pressed (S13)
The switching mechanism of the left ramp detects
an obstacle.
Check if the mechanism is pressed and remove the obstacle
50 S12 Ramp right side pressed (S12)
The switching mechanism of the right ramp detects
an obstacle.
Check if the mechanism is pressed and remove the obstacle
51 S16
Left limit switch pressed permanently
(S16)
The switch stays pressed
Check whether the switch can move freely and remove any
obstructions
52 S15
Right limit switch pressed permanently
(S15)
The switch stays pressed
Check whether the switch can move freely and remove any
obstructions
53 S15 limit switch pressed to drive direction (S15) The contact for the switch does not switch through Check whether all contacts of the switch switch.
54
S16
limit switch pressed to drive direction (S16)
The contact for the switch does not switch through
Check whether all contacts of the switch switch.
55 Maintenance due soon The maintenance interval is due shortly Contact your service technician for maintenance.
56
Maintenance due
Maintenance is overdue
Contact your service technician for maintenance.
57 Buffer battery empty
The battery on the main circuit board (CR2032) is
dead
Replace the battery on the main controller
58 Radio transmitter battery weak!
The hand-held remote control reports a weak
battery
Replace the batteries in the respective remote control (wireless
wall-switch).
59 Safety catch sensor deliver no pulses Catch sensor does not provide any pulses Check whether the sensor still switches and adjust it if necessary
60
Undefined Platform position, platform open
or close
No limit switch from the platform actuated with a
drive command
Bring the lift into a defined position by opening or closing the
platform.
10000 Power ON Restart the controller No action necessary
10001
Load Factory settings
Factory settings have been loaded
No action necessary
10002
EEPROM Fehler Parameter
An internal error has occurred in the circuit board
Contact your service technician
10003
EEPROM Fehler Zähler
An internal error has occurred in the circuit board
Contact your service technician
10004 Initialized Error Buffer An internal error has occurred in the circuit board Contact your service technician