13-10-614 Page 56
Oil Cooler Water Pressure Differential (Water-Cooled Heat Exchanger) - The water pressure
differential through the heat exchanger will depend on the supply pressure, flow rate, cooler tube
cleanliness and outlet pressure. The inlet and outlet water pressure may be checked at the pipe fittings
supplied by the customer.